COMMERCE BUSINESS DAILY ISSUE OF MAY 6,1998 PSA#2089Department of the Army, Headquarters, Military Traffic Management
Office, ATTN: MTTM-T Room 629, 5611 Columbia Pike, Falls Church, VA
22041-5050 81 -- 36 X 20' ISO DRY CARGOWORTHY CONTAINERS SOL DAMT01-98-Q-9913 DUE
050698 POC Sarah C. Wiley (703) 681-9770 WEB:
wileys@baileys-emh5.army.mil, wileys@baileys-emh5.army.mil. E-MAIL:
wileys@baileys-emh5.army.mil, wileys@baileys-emh5.army.mil. THIS
REQUIREMENT IS SET ASIDE FOR SMALL BUSINESS PARTICIPATION ONLY. PLEASE
INDICATE SIZE OF BUSINESS IN YOUR RESPONSE. STANDARD INDUSTRIAL CODE
CLASSIFICATION 3441, SIZE STANDARD 500 EMPLOYEES, APPLIES. The
Government requires the purchase of 20' cargo-worthy ISO containers as
described below. Subject containers must be delivered as specified in
the description provided. If the RDD provided below cannot be met,
please provide your earliest availability for delivery of any units
that are offered in response to this request for quotes. Please provide
unit price, drayage and all other related costs below as applicable.
All containers purchased by the Government must have not less than
(NLT) one set of fork lift pockets. Container(s) offered to the
Government must be in cargo worthy/sea worthy condition. Container(s)
must have current CSC inspection and be wind and water tight. Cargo/sea
worthy condition inspection incorporates the following: 1. ISO -- No
alteration of K-1,K-2, dimensions. 2. WELDS -- No cracked welds on the
welds of prime structural components. 3. PANELS -- Dents, bonds and
bows up to 50mm into the cube. 4. CORNER POSTS -- Dents to 25mm. 5. TOP
SEARAILS -- Dents to 25mm. 6. HEADERS -- Front 25mm, Rear 35mm. 7.
BOTTOM RAILS -- Dents up to 50mm (no limit on flanges). Flange comes up
to webs, except on bottom side rails. 8. FLP SIDES, CROSSMEMBERS
TUNNELS RAILS AND BOLSTERS -- Debris up to 75mm (no limit on flanges)
horizontal cuts in webs to 400mm. Flange cuts up to welds. 9. DOORS --
Operable, light & watertight and sealable. 10. FLOOR GOUGES -- Up to
15mm deep and 150mm wide, 5mm deep over 150mm wide, uneven adjacent
boards/threshold plate up to 5mm. 11. FLOOR SEPARATION -- Up to 10mm at
fastener. 12. RAIN GUTTERS & J BARS -- No interfering with the door.
13. VENTS -- Functioning and watertight or closed off. 14. MARKINGS --
All serial numbers and IS required markings must be legible. TIR and
CSC plates must be present. 15. GENERAL -- No missing door hardware. No
holes into the cube. No cuts except as noted above. No corrosion that
will not pass a hammer test. No hazardous cargo residues or foul odors.
The government will require inspection at depot of origin before
shipment. Containers are to be delivered FOB Destination. 98-085 36x20'
ISO Dry Containers delivered to: (36 units) Westinghouse Engineering
Products Division 5301 Sierra Vista Carlsbad, NM 88220 POC: Susan
Rivera (505) 234-5617 ALT POC: JOE SCHORK @ (703) 351-7918 Required
Delivery Date: 8 July 1998 Price Proposal: Qty Unit Price Extended
Price CLIN 0001 ___ EA $__ __ __ __ $__ __ __ ___ 20' ISO Container(s)
CLIN 0002 ___ EA $__ __ __ __ $__ __ __ &llmdash;__ Delivery Depot of
origin of units offered under this proposal. Name:__ __ __ __ __ ___
Street:__ __ __ __ __ ___ City/State/Zip:__ __ __ __ ___ All
responsible sources may submit an offer for consideration by the
government via e-mail(wileys@baileys-emh5.army.mil) or FAX (703)
681-9112 by 4:30 PM Eastern Time, 6 May 1998. The anticipated award
date is 15 May 1998. Note: The successful offeror is required to
provide release numbers for all containers as well as unit numbers so
that inspections can be ordered expeditionsly. The trucker must notify
the receiving POC 24 hours before delivery of the units. In addition,
the contractor must notify Joe Schork, SeaLand Logistics (703)
351-7918of the container numbers to be delivered BEFORE the containers
move from the depot of origin. (0122) Loren Data Corp. http://www.ld.com (SYN# 0388 19980506\81-0001.SOL)
81 - Containers, Packaging and Packing Supplies Index Page
|
|