COMMERCE BUSINESS DAILY ISSUE OF MAY 20,1998 PSA#2099Arnold Engineering Development Center, Attn: AEDC PKP, 100 Kindel
Drive, Suite A332, Arnold AFB TN 37389-1332 42 -- MOBILE "TUBE TYPE" OIL AND FUEL SKIMMING SYSTEM SOL
F40650-98-Q-0015 DUE 061998 POC Tony Clayborne, Contracting Officer,
(931) 454-7841 This requirement is for a mobile oil and fuel skimming
system ("tube type") to be an Oil Skimmer Model 6V or equal with the
following salient characteristics: minimum 40' tube collector system;
balanced mount complete with minimum 24' boom; mounted on a minimum 500
gallon trailer mounted tank; prewired with a on/off switch for the
skimmer; unit must accept 120V power; trailer must be a minimum 7 ton
tandem; neoprene impeller bronze pump prewired and piped into oil
skimmer, minumum 1 HP, 1725 rpm motor rated at 32 gpm @ 34.5 psi (H20);
explosion proof motor and all electrical components; fill gauge to
indicate liquid level from 1/4 to full; sight gauge, minimum 1 1/2"
plastic with plugged "T"s for cleaning; heater, skimmer spout heater,
heat tracing and insulation, covered with a minimum 1" insulation and
a weather proof cover, thermostat provided to control the heating
element; insulation, heat pads connected to fuel tank to prevent
freezing, pads are wired into the system and the entire tank is covered
with a minimum 1" fiberglass insulation and 24 gauge aluminized steel
sheet used to cover fiberglass insulation, all seams are protected with
silicone sealant, thermostat provided to control the heat pad;
collector tubing, minimum spare collector tubing of 200'; generator,
minimum 4,000 watts, 33.3 amps mounted to the oil skimmer, wired into
the oil skimmer for operation when power is not available, fuel tank
and cover, fuel tank to be minimum 15 gallons, minimum 12 V battery
with 360 cold crank amps. The system must be delivered within 30 days
of contract award. Oil Skimmer is considered the be the only known
manufacturer of the above requirements. Authority 10 U.S.C. 2304
(C)(1). Justification: Supplies and services required are available
from only one known responsible source and no other type of supplies or
services will satisfy agency requirements. This is not a request for
competitive proposals. No solicitation documents, specifications, or
drawings are available. Simple requests for an RFQ will not be
considered an affirmative response to this synopsis. Interested parties
may identify their interest and capability to respond to the above
requirements. See Note #22. (0138) Loren Data Corp. http://www.ld.com (SYN# 0244 19980520\42-0001.SOL)