Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF AUGUST 12,1998 PSA#2157

45CONS, 1201 Edward H. White II St, MS 7200, Patrick AFB, FL 32925-3237

66 -- XRF SPECTROMETER SYSTEM SOL F08650-98-TB132 POC Lear Matus, Contract Specialist (407) 494-9512 or Jimmy McDaniel, Contracting Officer (407) 494-7227 The Government intends to negotiate on a sole source basis with Philips Electronic Instruments Co of Alpharetta GA 30005 for the following requirement: Provide and install an XRF Spectrometer System, Philips Electronic Instruments Model PW2400, compatible with and utilizing existing multiple analysis crystals. System and options with the following salient characteristics: 1 each Sequential X-ray Spectrometer 3KW, 60kV, 125mA; 1 each X-ray Tube: Ceramic SST 3kW, 6kV, 125mA, 150 micro BE End Window; 2 each sets of 5 flow Counter Windows 2 micron PP; 2 each Primary Beam filter 100 micron Brass; 3 each Primary Beam Filter 200 micron A1; 1 each Primary Beam Filter 300 micron Brass;1 each Primary Beam Filter 750 micron A1; 1 each Beam Stop 1mm Pb; 1 each Primary Collimator, High Resolution, 0.15mm Spacing; 1 each Primary Collimator, Medium Resolution, 0.30mm Spacing; 1 each Primary Collimator, High Intensity, 0.70mm Spacing; 1 each Analyzing Crystal LiF200; 1 each Analyzing Crystal PE; 1 each Synthetic Multilayered Monochromator PX1; 1 each SuperQ Analytical Software MS Windows ; 1 each Computer, Gateway 2000, GPS-200 MHz (with prescribed options); 1 each HP Deskjet 870Cxi with Cable; 1 each R175 Water Cooled Water Chiller; 1 each Air Preparation Kit; 1 each Switch Box and Modem F/Remote Diagnostics; 1 each 47 Element 40mm Monitor disk; 1 each He Tank Adapter; 1 each He Flush System for Liquids; 1 each Set of 5 He Liquid Cups, 2400/2600; 1 each Inserts (includes 100 KAT P-2 cells); 1 each Semi-Q Software with Standards; 1 each Be Filter (substitute at install for one of above); On-site Training (approximately 2.5 days); Shipping FOB Destination. The applicable SIC code and size standard are 3826/500. Specifications, plans, or drawings relating to the procurement described are not available and cannot be furnished by the government due to proprietary information. Other interested parties desiring consideration for his requirement must submit detailed documentation of their technical capabilities and pricing information within 15 days of the date of this publication to: 45 CONS/LGCSA, Attn: Ms Lear Matus, 1201 Edward H. White II St, Patrick AFB, FL 32925-3237. Phone calls will not be accepted. The literature provided must sufficiently demonstrate the ability to meet the above requirement. Patrick AFB will not pay or otherwise reimburse respondents for information submitted.***** Posted 08/08/98 (W-SN234486). (0220)

Loren Data Corp. http://www.ld.com (SYN# 0413 19980812\66-0006.SOL)


66 - Instruments and Laboratory Equipment Index Page