|
COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 11,1998 PSA#2178Defense Supply Center Columbus, PO Box 16595, DSCC-PBAB, Columbus, OH
43216-6595 59 -- SYNCHRO, CONTROL TRA SOL SP0930-98-Q-A571 DUE 100298 POC Point
of Contact -- Melissa Kirk, Telephone Number -- 614-692-7827 WEB:
Defense Supply Center Columbus Solicitations on Web,
http://www.dscc.dla.mil/RFQ/. NSN: 5990-00-813-8808, Synchro,
Transmitter -- QTY 110 each to be delivered to Mechanicsburg, PA
17055-0789 within 100 days ADO -- Various increments solicited From/To:
75/99, 100/124, 125/149, 150/199, 200/249 -- See Note 26 -- See NOTE 9
-- All offered material must be In Accordance With (IAW) U S Army
Aviation And Missile (18876) Drawing 10182000. Additional technical
requirements and quality assurance provisions apply. These additional
requirements and provisions are contained in the solicitation that is
available on the WEB @ http://www.dscc.dla.mil/RFQ/ -- Manufacturers
that are currently waived for First Article Testing are: QMC
Technologies Inc. (14404) P/N 11CT1335 Litton Systems Inc. (99932) P/N
11CT4E/1-002 -- Available Technical Characteristics: Stator input
voltage rating in VOLTS 90.0 nominal; Stator input current rating 18.0
MILLIAMPERES nominal -- This is a Critical Application Item. All
material offered/supplied under this procurement mustbe new material.
Other than new material, residual inventory, and former Government
surplus property will not be considered for award. -- All alternate
sources require approval by the appropriate Technical Services Section.
-- Hard copies of this solicitation are not available. Requests for
hard copies of this solicitation will not be accepted. This
solicitation is open (on-the-street) concurrent with the posting of
this notice in the CBD and all offers must be received by posted
closing date (2 October 1998). Offers may be submitted by facsimile
transmission to: FAX 614-692-6913. -- The use of any Class I
Ozone-Depleting Substance (ODS) in the design, manufacturing, testing,
cleaning, or any other process for this item under any military or
federal specification, standard or drawing referenced in this item
description is "prohibited" unless the separate written approval of the
Contracting Officer is obtained. This prohibition supersedes all
specification requirements but does not alleviate any product
performance requirements. This does not apply to commercial items, as
defined in "FAR 11.001" or to part-numbered-only items. -- DLAD
52.246-9004, Product Verification Testing, applies. This clause is a
Government option that can only be invoked upon the cognizant contract
administration office notifying the contractor that PVT samples are to
be selected. -- All responsible sources may submit an offer/quote which
shall be considered. Posted 09/09/98 (W-SN247292). (0252) Loren Data Corp. http://www.ld.com (SYN# 0276 19980911\59-0011.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|