COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 16,1998 PSA#2222U. S. Environmental Protection Agency, Contracts Management Division
(MD-33), Attn: ORDSC, Research Triangle Park, NC 27711 A -- ORGANIC AEROSAL SAMPLER SYSTEM SOL RFQ-RT-99-E2B315 DUE 120998
POC Starry M. Jones, Contract Administrator, (919)541-2897; Julio
Lopez, Contracting Officer, (919)541-4474 E-MAIL: click here to contact
the contract specialist via, jones.starry@epa.gov. The Environmental
Protection Agency has a requirement for a semi-volatile organic aerosol
sampler system to consist of a cylone, a fitting to connect two
denuders in parallel, 2-100 lpm denuders, housing to maintain denuders
at ambient 5 C, filter holder, 2-XAD holders, 2-filter holders,
fitting to connect XAD holders to flow controller, one flow controller
and one pump, valves to allow computer operation of either denuder
system, data system to record output of flow controller, ambient and
denuder temperatures and relay to start the pump. Inlet: cyclone with
50% cutpoint 2.5 m at 100 liters/minute. Denuder: 8 channel etched
glass denuder with 1mm channel, 52mm OD, total length 650mm with etched
of 600mm centered in denuder. Flow rate through each denuder is 100
liters/minute. Each denuder to be coated with XAD microresin. Denuder
housing: sufficient in size to contain two denuders, filter and XAD
holders and maintain temperature within 5 C of ambient. Flow
controllers and pump: system to consist of flow controller and pump.
Flow controller and pump must maintain flow within 10% of 100
liters/minute under with ambient temperature between -20 to 40 C. If
possible a flow controller based on the volumetric fow at ambient
temeprature and pressure is preferred. System to be sized to collected
ambient air sample of PM2.5 for 24 hours at up to 50 g/m3. Sample flow
is 100 liters/minute through cyclone and denuder, 3 m Zefluor, quartz,
or Teflon coated quartz filter (diameter 9cm), and bed of XAD2. XAD2
bed must be sufficient to trap naphthalene under above conditions. Flow
controller and pump to be inclosed in weather protected housing. Data
acquisition system: sensors for monitoring and storing ambient and
denuder temperature, outputs from mass flow meter controller, vacuum
before flow controller, time of day, and relay to turn pump system on
and off. Data to be recorder with data acquisition system. The
Environmental Protection Agency anticipates an award of a fixed price
purchase order using Simplified Acquistion Procedures. This procurement
is a total small business set aside. All interested parties must submit
a written request for the RFQ within fifteen (15) days of the date of
this announcement to the Attention of Starry M. Jones, U. S.
Environmental Protection Agency, Contracts Management Division, MD-33,
79 T. W. Alexander Drive, Research Triangle Park, NC 27711. No
telephone request will be honored. All responsible sources may submit
a quote which shall be considered by the Agency. Posted 11/09/98