COMMERCE BUSINESS DAILY ISSUE OF MARCH 1,1999 PSA#229220 CONS/LGCC, PO Drawer 52610, Shaw AFB, SC 29152-2610 N -- BUILD AND INSTALL MAP TABLE/CABINET SOL F3860199T0160 DUE 031299
POC POC: SSgt Jackie Williams (803)895-6005 Ext 256 WEB: 20th
Contracting Squadron's Contractor Assistance Site,
http://www.shaw.af.mil/20fw/20log/contracting/index.htm. E-MAIL: SSgt
Jackie Williams, jacquelin.williams@shaw.af.mil. This is a sources
sought synopsis for parties interested in submitting a quotation for
building and installing a map table/cabinet. This requirement is below
the threshold for formal synopsizing. This will be the only form of
synopsis issued for this requirement. This announcement is a request
for information only and is not a Request for Proposal (RFP), Request
for Quotation (RFQ), or announcement of solicitation and is not to be
construed as a commitment by the Government to issue a solicitation or
ultimately award a contract. An award will not be made on
offers/proposals received in response to this notice. The Government
will not provide payment for any material provided in response to this
synopsis, nor will the Government return any material provided. The
work includes but is not limited to providing all labor, tools,
material, equipment, and transportation necessary to build and install
one map table/cabinet. The construction shall be mortise and tenon
with glued and stapled joints, also using hardwood blocking. The sides,
face and bottom shall be " plywood, shelves shall be 5/8" plywood and
the backs shall be " plywood. All exposed surfaces shall be covered
with laminated plastic. Base units shall be made in sections as
indicated to fit through a standard 3' x 6'8" door. Install
self-closing, 3-way adjustable concealed hinges. Hinges shall provide
165-degree swing. Drawer slides shall be full extension type with
100-lb capacity. Drawer and door pulls shall be "U" shaped aluminum
with satin finish. Drawer units shall have legal size hanging file
system. Light table section shall have a U.L. approved, 3 tube, 2'
light system with a minimum of 6' cord. Construct one (1) map
table/cabinet and install in building 1605, Shaw AFB, SC. A faxed copy
of applicable dimensions and drawings may be requested by contacting
SSgt Jackie Williams at (803) 895-6005, ext. 256. All interested
parties should submit their response no later than 12 March 1999. If
interested parties want to submit their designs or ideas ofa similar
product, they may do so in response to this Request for Information;
and they will be evaluated by the government. Interested parties to
this synopsis should be registered in the Central Contractor Registry
(CCR). Responses may be sent via letter to the attention of SSgt Jackie
Williams at 305 Blue Jay Street, Shaw AFB, South Carolina 29152. Faxed
responses may be sent to (803) 895-6018; e-mail responses may be sent
to jacquelin.williams@shaw.af.mil. Please include in your response a
point of contact, business name, phone number, and business size. A
solicitation will be issued after 12 March 1999. Sources derived from
this synopsis will be compiled in a database for possible future
requirements of the same nature. Posted 02/25/99 (W-SN302440). (0056) Loren Data Corp. http://www.ld.com (SYN# 0070 19990301\N-0001.SOL)
N - Installation of Equipment Index Page
|
|