COMMERCE BUSINESS DAILY ISSUE OF MARCH 4,1999 PSA#2295National Cancer Institute, Research Contracts Branch, PSAS, 6120
Executive Blvd, EPS/Room 638, Bethesda, MD 20892-7227 66 -- INSTRUMENTS & LABORATORY EQUIPMENT SOL RFQ-NCI-90046 DUE 032399
POC Cynthia Brown, Purchasing Agent, 301-402-4509, Todd Cole,
Contracting Officer  The National Institutes of Health (NIH),
National Cancer Institute (NCI), Advanced Technology Center (ATC) plans
to procure a Biologer Duo-Flow System with Model 2128 FractionCollector
from Bio-Rad Laboratories, Life Science Group, 2000 Alfred Nobel Drive,
Hercules,CA 94547. The system shall have the following salient
characteristics, features, and specifications:1) Dual pump system with
inherent biocompatibility. Associated pumphead shall be capable of
providing material at a flow rate of 10 milliliters per minute at 3500
pounds per square inch of pressure. 2) Includes a tri-level racking
system, and a sample inject valve that operates in a make-before-break"
manner. 3) Provides for a 254/280 nanometer filter and a 5 millimeter
ultraviolet flow cell, conductivity flow cell. 4) Includes a fraction
collector with collection rack and diverter valve. 5) Dual flow
controller electronics shall include the following minimum personal
computer (PC) characteristics: (a) "Pentium" class 300 megahertz clock
speed microprocessor, (b) Random access memory (RAM) of 32 megabytes,
(c) 6 gigabyte hard drive,(d) 3.5 inches floppy diskette drive, (e)
32X compact disk drive, and (f) Multimedia, 17 inches color monitor
with built-in speakers ( NOTE: All computer equipment must be Year 2000
Compliant). The system shall also be compatible to the Pharmacia Mono
Q HR5/5, Mono Q HR 10/10, and Mono SHR 5/5 Models in that the pressure
levels may be adjusted /switched to without changing the pump heads or
requiring additional hardware and software. Thus, a seemless
integration within ongoing experiments can be achieved with this system
without the downtime of changing pump heads. Bio-Rad laboratories, Life
Science Group, is the only source known to NCI that can meet the above
specifications. However, if any interested party believes it can meet
the above requirement, it may submit a statement of capabilities. The
capability statement and any other information furnished must be in
writing and must contain material in sufficient detail to allow NCI to
determine if the party can meet the requirement. Capability statements
must be received in the contracting office by 2:00 p.m. EST, on March
23, 1999. If you have any questions please contact Cynthia Brown,
Purchasing Agent, on (301) 402-4509. A determination by the Government
not to compete this proposed requirement based upon responses to this
notice is solely within the discretion of the Government. Information
received will be considered solely for the purpose of determining
whether to conduct a competitive procurement. No collect calls will be
accepted. Please site the solicitation number: RFQ-NCI-90046. Posted
03/02/99 (W-SN303660). (0061) Loren Data Corp. http://www.ld.com (SYN# 0257 19990304\66-0004.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|