COMMERCE BUSINESS DAILY ISSUE OF APRIL 3, 2001 PSA #2821
SOLICITATIONS
28 -- REPAIR OF F108 FAN BOOSTER VANE ASSYS
- Notice Date
- March 30, 2001
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, OC-ALC -- (Central Contracting), 3001 Staff Drive, Ste 1AG76A, Tinker AFB, OK, 73145-3015
- ZIP Code
- 73145-3015
- Solicitation Number
- F34601-01-R-65767
- Response Due
- April 30, 2001
- Point of Contact
- Madeline Clements, Contracting Officer, Phone 405-739-4496, Fax 405-739-4237, Email madeline.clements@tinker.af.mil
- E-Mail Address
- Madeline Clements (madeline.clements@tinker.af.mil)
- Description
- Presolicitation Notice Date Submitted: 28-MAR-2001 OC-ALC/LPDPA DIR CONTRACTING/PROPULSION 3001 STAFF DR STE 2AG1/106C TINKER AIR FORCE BASE OK 73145-3032 J -- REPAIR F108 FAN BOOSTER VANE ASSYS SOL F34601-01-R-65767 DUE 043001 Madeline Clements/Lpdpa/[405]739-4496, For additional information contact Madeline Clements/Lpdpa/[405]739-4496 Services, non-personal: The Contractor shall furnish all required labor, facilities, equipment and all material to accomplish overhaul/repair of the F108/CFM56-2B Booster Vane Assemblies. A firm fixed price requirements type contract is contemplated for one year, plus 4 one-year options. The items and best estimated quantities are as follows: 1st Stage OUTPUT: NSN 2840-01-465-1987PN, P/N 301-288-145-0 OR 301-288-147-0 OR 301-288-148-0; INPUT: NSN 2840-01-187-3199PN, 2840-01-465-1987PN, P/N 301-288-131-0, 301-288-135-0, 301-288-144-0 OR 301-288-148-0. 2nd Stage OUTPUT: NSN 2840-01-187-3200PN, P/N 301-288-335-0 OR 301-288-240-0 OR 301- 288-244-0 OR 301-288-245-0 OR 301-288-251-0; INPUT: NSN 2840-01-187- 3200PN, P/N 301-288-335-0, 301-288-240-0, 301-288-244-0. 301-288-245-0 OR 301-288-251-0. 3rd Stage OUTPUT: NSN 2840-01-187-8262PN, P/N 301-288-337- 0, 301-288-343-0, 301-288-351-0; INPUT: NSN 2840-01-187-8262PN, P/N 301- 288-337-0, 301-288-343-0 OR 301-288-351-0. 4th Stage OUTPUT: NSN 2840-01- 189-2638PN, P/N 301-288-454-0 OR 301-288-456-0 OR 301-288-471-0; INPUT: NSN 2840-01-189-2638PN, P/N 301-288-454-0, 301-288-456-0 OR 301-288-471-0. BEST ESTIMATED QUANTITIES are as follows: 1ST stage, 1ST year 11 EA, 2ND year 10 EA, 3RD year 8 EA, 4TH year 8 EA and 5TH year 4 EA. 2ND stage, 1ST year 13 EA, 2ND year 13 EA, 3RD year 12 EA, 4TH year 12 EA and 5TH year 11 EA. 3RD stage, 1ST year 10 EA, 2ND year 10 EA, 3RD year 10 EA, 4TH year 10 EA and 5TH year 8 EA. 4TH stage, 1ST year 5 EA, 2ND year 5 EA, 3RD year 4 EA, 4TH year 3 EA and 5TH year 3 EA. The Fan Booster Vane Assy is a coated stainless steel annulus directional air flow device. Stage 1 vane assy has 82 vanes, stage 2 vane assy has 107 vanes, stages 3 and 4 vane assys each have 119 vanes. The stator vanes are welded to the outer shroud and retained on the inner shroud by abradable material. The repair/rework will be accomplished in accordance with (IAW) applicable CFMI (CFM56-2B)Engine Shop Manual, 72-21-09. The 1st Stage Fan Booster Vane assy will be reworked/re-identified with blade locks per CFMI service bulletin (CFM56- 2B) 72-536. Repair will be performed utilizing the "On-condition" maintenance concept, which is based on repairing an item only to the extent necessary to return the item to a serviceable condition as determined by workscope planning. There is no Government Furnished Tooling or technical data available. The Government's intent is to use commercial practices, manuals, and industry standards wherever possible in support of the repair of these items. Solicitation will be issued to the pre-qualified sources listed below: Propulsion Technologies Corporation, Miami Florida and General Electric Engine Services, Cincinnati Ohio. Solicitation issue date is approximately 30 March 2001 and the date set for receipt of offers will be approximately 30 April 2001. Award may include options. For solicitation and information, please contact Madeline Clements/LPDPA at the email shown below or Phone 405-739-4496 or FAX 405-739-4237. Requests for a copy of the solicitation should be submitted in writing. It should be noted that all contractors are required to be registered in the DOD Central Contractor Registration (CCR) database prior to any award. The approximate issue/response date will be 30 MAR 2001. Written procedure will be used for this solicitation. To: General Electric, Cincinnati Oh 45215 1988. To: Propulsion Tech Corp, Miami Fl 33122 1045. No telephone requests. Only written or faxed requests received directly from the requestor are acceptable. All responsible sources solicited may submit a bid, proposal, or quotation which shall be considered. Click here to reach Tinker AFB Central Contracting Synposes at EPS Click Here to E-mail Buyer
- Web Link
- Visit this URL for the latest information about this (http://www.eps.gov/cgi-bin/WebObjects/EPS.woa/wa/SPF?A=P&P=F34601-01-R-65767&L=902)
- Record
- Loren Data Corp. 20010403/28SOL003.HTM (I-089 SN50H8I0)
| 28 - Engines, Turbines and Components Index
|
Issue Index |
Created on March 30, 2001 by Loren Data Corp. --
info@ld.com
|
|
|
|